ENERGY METERS
Three-phase, active multifunctionalå




Mercury 231 ÀT


Meters are designed for registration of active energy in one direction in 3- or 4-wire networks of alternating current and operate either autonomous or within AMM

Basic functions:
  • Measurement, registration, storage, output to LCD monitor and transmission through interfaces IrDA of the following data:
    - quantity of registered active energy separately by each tariff and total of all tariffs
    • total from indications reset
    • for current day and for the beginning of a day
    • for previous day and for the beginning of a day
    • for current month and for beginning of a month
    • for each of 11 previous months and for the beginning of month
    • for current year and for beginning of a year
    • for previous year and for beginning of a year
  • Tarifficator of meter provides possibility of registration by 4 tariffs in 16 timing zones of a day for 4 types of days. Each month of a year is programmed with individual timetable. Minimum tariff working interval within a day – 1 minute
  • Additionally meter provides output to LCD indicator and transmission through wire interfaces of the following network values:
    • instantaneous values of active power by each phase and by phases total;
    • functioning values of phase currents, voltages, angles between network frequency phase voltages;
    • network frequency;
    • power factors by each phase and by phases total
  • Input of active power and energy limits and programmable control of external consumer switch off load devices in case limits are exceeded.
  • Meters programming in the mode of phases summation “on module” to prevent energy theft if meter current circuits connection phasing is wrong.
  • Meter journals (circle, 10 records for each event) register:
    • meter on/off time
    • phases 1,2,3 on/off time
    • time of phase voltage exceeding/returning back from permitted limits
    • devices opening/closing time;
    • last programming time
    • tariff timetable correction time
    • time of exceeding set energy and power limits
Technical specifications
  • Accuracy class 0.5s, 1.0;
  • interfaces: IrDA;
  • measuring power, currents, voltages, cos F;
  • PLC modem can be embedded for data transmission on power line 220V (depending on modification);
  • one standard galvanic unbound telemetric outputs (DIN 43864);
  • meters operate towards values increase in case of any wrong phasing of current circuits;
  • electronic seal;
Documents

Additional functions (modifications with F index ):

  • Storage of single-channel archive of average power values of active energy power profile with voluntary integration time from 1 to 45 minutes with step 1 minute. With 30-minutes duration of integration the archives overflow time is 85 days.


PLC interface provide:

Transmission of the following data about consumed energy with growing total

- starting from beginning of meter operation on tariff and phases sum in case meter is programmed in one-tariff mode;

- starting from beginning of meter operation on current tariff and phases sum on the moment of request in case meter is programmed in multi-tariff mode;

Receiving of the following data:

- built-in modem network identifier;

- command of temporal switch to auxiliary data transmission;

- current date and time


Basic specifications

Characteristics values
Accuracy class for
   - active energy

0,5S or 1,0
Nominal voltage, V 3*220/380
Nominal (max) current, A 5(10); 5(60)
Maximum current within 0,5 s, À
  - for Inom=5À

150
Sensitivity for measuring
   - transformer connection , Wò
   - direct connection , Wò

4,125 (1,375 for phase )
8,25 ( 2,75 for phase )
Active / full consumable power by each meter parallel circuit, W/VA not over 0,5 / 7,5
Full power, consumed by current circuit, not over V*A 0,1
Number of tariffs 4
Number of tariff seasons (months) 12
Exchange speed, bit/s:
- through infrared port;


9600
Transmission ratio of basic/verification output, imp/kW, imp/kVAr:

for ART-01 (Unom 220 V, I nom 5 A)
for ART-03 (Unom 220 V, I nom 5 A)



1000
32000
Data safety in case of power supply failure, years
   - constant data
   - operative data

40
10
Data protection two access levels and hardware protection of metrological coefficients memory
Temperature range, °Ñ from -40 to +55
Interval between verifications, years 10
Mass, kg not over 0,8
Dimensions (length, width, height), mm 142*157*65
Warranty period, years 3

Performance versions

Meter designation Nominal voltage,
V
Nominal (max) current, A Accuracy class for measuring active energy Communication interface

Additional

"Mercury 231AT-XX" power meter with basic functions

ÀÒ-01 I 3*220/380 5(60) 1,0 IrDA Event log
ÀÐÒ-03 Ñ(R) 3*220/380 5(10) 0,5S IrDA Event log

"Mercury 231AT-XX" power meter with basic functions and additional functions

231ÀÒ-01 FIN 3*220/380 5(60) 1,0 IrDA Event log
load profile
231ÀÒ-03 FIN 3*220/380 5(10) 0,5S IrDA Event log
load profile

"Mercury 231AT-XX" power meter with basic functions and PLC modem

231ÀÒ-01 IL 3*220/380 5(60) 1,0 IrDA,
PLC-ìîäåì
Event log
231ÀÒ-03 IL 3*220/380 5(10) 0,5S IrDA,
PLC-ìîäåì
Event log

In meter designation:


Mercury 231AT-XX FILN


À – active energy,
T – internal tarificator,
F – power profile, event log
I – infrared port
N – electronic seal

outline drawing