ENERGY METERS
Three-phase, active/reactive |
|
Mercury 230 ÀR
Meters are designed for registration of active and reactive energy in one direction in 3- or 4-wire networks of alternating current and operate either autonomous or within AMR.
Meters provide:
- Energy registration by each phase of three-phase network in one- or multi-tariff (switching by interface signals) modes as well total on all phases.
- Indication on LCD active and reactive energy with growing total from indications reset on each tariff and on tariff sum..
- Measuring of instantaneous values of active, reactive and full power on each phase ond on phases sum with indication of direction;
- Measuring by phases: current, voltage, frequency, cos F, angles between phase voltages.
- Programmable control of external devices of consumer load switching on/off.
- Transmission of measuring results through power line 220/380V (only consumed energy) and through CAN, RS-485 (all existing data).
- Meters programming in phases summation mode “by module” to avoid energy theft if meter current circuits connection phasing is wrong.
- Meter internal clock correction.
|
| Technical specifications |
- Accuracy class 0.5s, 1.0s
- interfaces: CAN, RS-485
- measuring network values
- tariff switching (up to four) is realized with interface signals
|
| Documents |
|
|
Meters indicate on LCD display: |
- Consumed active and reactive energy value for each tariff (up to four) and total for all tariffs with growing total and accuracy up to hundredth parts of kWh and kVAh;
- Phase voltage and current in each phase;
- Measured value of active, reactive and full power (integration time 1 s) both for each phase and total for three phases with indication of quadrant, in which there is a full power vector;
- Power factor for each phase and total for three phases;
- Angles between phase voltages;
- Network frequency;
- Current date and time
- Power line modem values
- Modem signal level sign
|
Meters provide reading by external PC through interfaces «CAN» , «IrDA» or RS-485 of the following values and data: |
| Parameters |
Programming |
Reading |
• interface exchange parameters (prohibited for infrared port) |
- exchange speed; |
+ |
+ |
- evenness/unevenness control; |
+ |
+ |
- system time-out duration multiplier; |
+ |
|
• changing passwords of first (consumer) and second (seller) access level to data |
+ |
|
| • registered active and reactive energy of direct and reverse direction for each of 4 tariffs and total for tariffs;
- total from indications reset;
- for current date;
- for the beginning of current date;
- for previous date;
- for the beginning of previous date;
- for current month;
- for the beginning of current month;
- for each of previous 11 months;
- for the beginning of each of previous 11 months;
- for current year; - for the beginning of current year;
- for last year;- for the beginning of last year
|
|
+ |
• auxiliary values: |
- instantaneous values (with integration time 1 s) of active, reactive and full power on each phase and on phases total; with indication of direction (full power vector position); |
|
+ |
- functioning values of phase voltages and currents on each phase; |
|
+ |
- power factors on each phase and on phases total with indication of direction (full power vector position); |
|
+ |
- angles between phase voltages; |
|
+ |
- network frequency; |
|
+ |
•meters individual values: |
- network address; |
+ |
+ |
- serial number; |
|
+ |
- manufacturing date; |
|
+ |
- meter position; |
+ |
+ |
- accuracy class on active energy; |
|
+ |
- accuracy class on reactive energy; |
|
+ |
- phases summation sign (taking into account sign/ by module);- meter performance version (one-directional/overflowing); |
+ |
+ |
- nominal voltage; |
|
+ |
- nominal current; |
|
+ |
- transformation coefficient by voltage; |
+ |
+ |
- transformation coefficient by current; |
+ |
+ |
- meter constant in basic mode; |
|
+ |
- operation temperature range; |
|
+ |
- impulse output modes (basic/verification); |
+ |
+ |
- software version; |
|
+ |
• indication modes: |
- indication period (1..255 seconds); |
+ |
+ |
- consumed energy indications displaying duration on current tariff (5..255 seconds) in automatic mode; |
+ |
+ |
- consumed energy indications displaying duration on non-current tariff (5..255 seconds) in automatic mode; |
+ |
+ |
- time-out duration (5…255 seconds) during switching from manual to automatic mode |
+ |
+ |
• straight direction active power and energy set limits exceeding control values: |
-control mode (permission/prohibition) for exceeding straight direction active power set limit; |
+ |
+ |
- control mode (permission/prohibition) for exceeding straight direction active energy set limit; |
+ |
+ |
- set power limit values; |
+ |
+ |
- set energy limit values separately for each of four tariffs; |
+ |
+ |
- impulse output mode (pins 21, 26) (telemetry/load switch off unit control mode); |
+ |
+ |
- load switch off unit control mode (load switched on/off); |
+ |
+ |
| • meter self-diagnostic condition. |
|
+ |
Transmission of the following data about consumed energy with growing total |
- starting from beginning of meter operation on tariff and phases sum in case meter is programmed in one-tariff mode; |
- starting from beginning of meter operation on current tariff and phases sum on the moment of request in case meter is programmed in multi-tariff mode; |
• Receiving of the following data: |
- built-in modem network identifier; |
- command of temporal switch to auxiliary data transmission; |
- current date and time |
| Characteristics |
values |
Accuracy class for
- active energy
- reactive energy |
0,5S or 1,0S
1,0 or 2,0 |
| Nominal voltage, V |
3*57,7/100 or 3*220/380 |
| Nominal (max) current, A |
5(7,5); 5(50); 10(100) |
Maximum current within 0,5 s, À
- for Inom=5À
- for Inom=10À |
150
200 |
Sensitivity for measuring
- active energy, Wò
- reactive energy, VAr |
0,36; 1,38
0,72; 2,75 |
| Active / full consumable power by each meter parallel circuit, W/VA not over |
0,5 / 7,5 |
| Full power, consumed by current circuit, not over V*A |
0,1 |
| Number of tariffs |
1 (int), 4(ext) |
| Exchange speed, bit/s:
- through interface CAN and RS-485;
- through infrared port;
|
300, 600, 1200, 2400, 4800, 9600
9600
|
| Transmission ratio of basic/verification output, imp/kW, imp/kVAr:
for ART-00 (Unom 57,7 V, I nom 5 A)
for ART-01 (Unom 220 V, I nom 5 A)
for ART-02 (Unom 220 V, I nom 10 A)
for ART-03 (Unom 220 V, I nom 5 A) |
5000/160000
1000/32000
500/16000
1000/160000 |
Data safety in case of power supply failure, years
- constant data
- operative data |
40
10 |
| Data protection |
two access levels and hardware protection of metrological coefficients memory |
| Temperature range, °Ñ |
from -40 to +55 |
| Interval between verifications, years |
10 |
| Mass, kg |
not over 1,5 |
| Dimensions (length, width, height), mm |
258*170*74 |
| Warranty period, years |
3 |
|
|
Meter designation |
Nominal voltage, V |
Nominal (max) current, A |
Accuracy class for active/reactive energy |
Communication interface |
Mercury 230 AR-XX C(R) of direct and transformer connection |
| ÀR-00 Ñ(R) |
3*57,7/100 |
5(7,5) |
0,5S / 1,0 |
CAN èëè RS485 |
| ÀR-01 Ñ(R) |
3*220/380 |
5(50) |
1,0S /2,0 |
CAN èëè
RS485 |
| ÀR-02 Ñ(R) |
3*220/380 |
10(100) |
1,0S / 2,0 |
CAN èëè
RS485 |
| ÀR-03 Ñ(R) |
3*220/380 |
5(7,5) |
0,5S / 1,0 |
CAN èëè
RS485 |
Mercury 230 AR-XX CL of direct and transformer connection with built-in PLC modem |
| ÀR-01 ÑL |
3*220/380 |
5(50) |
1,0S /2,0 |
CAN,
PLC-ìîäåì |
| ÀR-02 ÑL |
3*220/380 |
10(100) |
1,0S /2,0 |
CAN,
PLC-ìîäåì |
| ÀR-03 ÑL |
3*220/380 |
5(7,5) |
0,5S / 1,0 |
CAN,
PLC-ìîäåì |
| In meter designation: |

 |
|