Automated meter management (AMM)
|
|
AMR “Mercury PLC”
PLC equipment
PLC-I
PLC-II
Documentation and Software
|
The system of electric energy selling using RFID SMART cards
|
|
|
Energy meters Three-phase
|
Three-phase multitariff |
Three-phase, multifunctional, active/reactive, multi-tariff
Mercury 233ART2 |
Measuring and tariff registration of active and reactive energy and power in one direction or two direction. Registration of losses.
— Accuracy class A/R: 0,2S/0,5; 0,5S/1,0; 1,0/2,0
— Nom. voltage: 57,7 V; 230 V
— Nom. current 5А; 10А (max. up to100 А)
Meter measures three-phase network values (phase currents, voltages, power, etc.),stores load profile and losses profile, keeps events journal, controls load. Great choice of interfaces for application in different AMR including PLC modem.Load shed built-in relay. If included in meter network combined through rs485(CAN) interface in provides remote access to any meter through GSM channel
|
| interfaces: GSM, RS-485(1 or 2), optoport, PLC-II |
|
| |
Meter – GSM communicator
Mercury 230ART(2) (with index "G") |
Registration of full energy and losses with transmission of accumulated data through built-in GSM-modem. Meter measures three-phase network values (phase currents, voltages, power, etc.),stores load profile and losses profile, keeps events journal, controls load. Great choice of interfaces for application in different AMR including PLC modem.Load shed built-in relay
If included in meter network combined through rs485(CAN) interface in provides remote access to any meter through GSM channel. Functional capabilities are similar to meters of this series. |
| interfaces: GSM, RS485(CAN), IrDA |
|
| |
Three-phase, multifunctional, active/reactive, multi-tariff
Mercury 230ART (with index "P")and Mercury 230ART2 |
Measuring and tariff registration of active and reactive energy and power in one direction or two direction. Registration of losses.
— Accuracy class A/R: 0,5S/1,0; 1,0/2,0
— Nom. voltage: 57,7 V; 230 V
— Nom. current 5А; 10А (max. up to100 А)
Meter measures three-phase network values (phase currents, voltages, power, etc.),stores load profile and losses profile, keeps events journal, controls load. Great choice of interfaces for application in different AMR. |
| interfaces: RS-485(CAN), IrDA |
|
| |
Three-phase, multifunctional, active/reactive, multi-tariff
Mercury 230ART |
Measuring and tariff registration of active and reactive energy and power in one direction or two direction. Registration of losses.
— Accuracy class A/R: 0,5S/1,0; 1,0/2,0
— Nom. voltage: 57,7 V; 230 V
— Nom. current 5А; 10А (max. up to100 А)
Meter measures three-phase network values (phase currents, voltages, power, etc.). Great choice of interfaces for application in different AMR including PLC modem. |
| interfaces: RS-485(CAN), IrDA, PLC-I |
|
| |
Three-phase, multifunctional, active multi-tariff
Mercury 231 AT |
Measuring and registration of active energy in one direction in three-phase networks of alternating current with frequency 50Hz. Meter measures three-phase network values (phase currents, voltages, power, etc.), keeps events journal, controls load.
— Accuracy class: 1.0
— Nom. phase voltage: 230 V
— Nom.(max.) current 5(60)А |
| interfaces: IrDA |
|
Three-phase one-tariff |
Three-phase, active/reactive energy
Mercury 230AR |
Measuring and registration of active and reactive energy in one direction in three-phase networks of alternating current with frequency 50Hz. Meter measures values of three-phase network (phase currents, voltages, powers, etc.). Possibility of tariff zones switching and consumer load control through interface signals.
— Accuracy class: 0,5S/1.0; 1,0/2.0
— Nom. phase voltage: 57,7 V; 230 V
— Nom.(max.) current 5(50)А; 10(100)А |
| interfaces: CAN, RS485, PLС-modem |
|
| |
Three-phase, active energy
Mercury 230AM |
Measuring and registration of active energy in one direction in three-phase networks of alternating current with frequency 50Hz.
— Class: 0,5S; 1,0
— Voltage:57,7 V; 230 V
— Nom. current 5А; 10А (max. up to 100 А)
– Anti-reverse electromechanical registration device
|
| Telemetric channel |
|
| |
Three-phase, active energy
Mercury 231 AM |
Measuring and registration of active energy in one direction in three-phase networks of alternating current with frequency 50Hz.
— Class: 1,0
— Voltage: 230 V
— Nom. current 5А (max. up to 60 А)
– Anti-reverse electromechanical registration device
|
| Telemetric channel |
|
| |
Energy meters Single-phase
|
Single-phase multitariff |
One-phase, multi-tariff
Mercury 200 |
Measuring and tariff registration of energy. Modern design. Installation on DIN-rack of with screws. Possibility of consumer load control. Meter measures phase network values (phase currents, voltages, power).
— Accuracy class: 1,0;
— Nom. phase voltage: 230 V;
— Nominal (max) current: 5(60)А;
— four tariffs
|
| interfaces: CAN, PLС-I |
|
| |
| One-phase, multi-tariff Mercury 203.2T |
 Measuring and tariff registration of energyl. Meter measures phase network values (phase currents, voltages, power), stores load profile, keeps events journal, controls load.
—Accuracy class: 1,0;
—Unom. -230 V;
—Inom(max)-5(60)А;
—four tariffs.
Load shed built-in relay
|
| interfaces: RS-485, PLC-II, GSM, optoport |
|
| |
| One-phase, multi-tariff Mercury 206 |

Measuring and tariff registration of active and reactive energy and power.
Modern design. Installation on DIN-rack. Meter measures phase network values (phase currents, voltages, power), stores load profile, keeps events journal, controls load.
— Accuracy class: 1,0;
— Unom. 230 V; Inom(max) 5(60)(80); 10(100)А;
— four tariffs
.
Load shed built-in relay.
|
| interfaces: RS485, PLC-I, optoport |
Single-phase one-tariff |
| One-phase Mercury 201 |
Active energy registration in lines 230V. accuracy class 1,0. Nominal current 5(60) or 10(80)А. Current sensor shunt. Indication of data on LCD or calculation device of bobbin-type, protected from external electromagnetic influence and with reverse motion stopper. Installation on DIN-rack or with screws. Small size. Versions with PLC-modem for data transmission on power line 230V.
|
| Telemetric channel, PLС-I |
|
| |
| One-phase Mercury 202 |
Active energy registration in lines 230V. accuracy class 1,0. Nominal current 5(60) or 10(80)А. Current sensor shunt. Meters are designed for replacement of old induction ones and have totally conformable installation and overall dimensions.
|
| Telemetric channel, PLС-I |
|
| |
| One-phase Mercury 203 |
Active energy registration in lines 230V. accuracy class 1,0. Nominal (max) current 5(80)А.
Two current sensors : Shunt in phase chain ; Current transformer in electric circuit of zero;
Modified led indication of operation mode:
«Mains» meter is turned on;
«Ground» indicates inequality of current in phase and zero cables;
«Reverse» indicate inverse meter connection
|
| Telemetric channel |
|
| |
|